Microwave Motion Sensor Module Doppler Radar Detector (HW-M08)

Model NO.: HW-M08
Condition: New
Usage: Ray Sensor
Theory: Optical Sensor
Output: Analog Sensor
Frequency: 10.525GHz
Input Voltage: 6-24V
Output Voltage: 5V
Current: <5mA
Distance: 1-5m
Time: 300S
Size: 13.5*30*6mm
Trademark: None
Transport Package: Standard Packaging
Specification: CE
Origin: Shenzhen, Guangdong
HS Code: 9030900090
Model NO.: HW-M08
Condition: New
Usage: Ray Sensor
Theory: Optical Sensor
Output: Analog Sensor
Frequency: 10.525GHz
Input Voltage: 6-24V
Output Voltage: 5V
Current: <5mA
Distance: 1-5m
Time: 300S
Size: 13.5*30*6mm
Trademark: None
Transport Package: Standard Packaging
Specification: CE
Origin: Shenzhen, Guangdong
HS Code: 9030900090
Microwave Motion Sensor Module Doppler Radar Detector(HW-M08)

1.Detail:
HW - M08 microwave module adopts the planar antenna transmitting and receiving. Induction object for moving objects (or car), after induction to the output voltage signal, for active microwave induction, induction angle is 90degree.Widely used in security monitoring, intelligent systems, control of lamps and lanterns, automatic doors, garage, corridor, roads etc

2.Features:
1).Not affected by temperature, humidity, air, dust, noise, light and dark, not affected by the direction of movement, strong anti-jamming capability.
2) Microwave module is a pattern to launch out, no dead Angle blind area, wide coverage.
3)Microwave is reflected more easily in the process of transmission, sensitivity inside will be better, outdoor is a bit poor.
4)Signal can pass through the glass, obstacles such as trees, plastic (this will make the induction distance attenuation somewhat)
5) Professional design planar with antenna, low power consumption, ROHS, high product consistency.

We can custom the module as your request,welcome to ask me.OEM is highly welcomed.

3.Technical parameters:
Frequency 10.525GHZ
Current <5mA
Input Voltage 6-24V
Output Voltage 5V
Size 13.5*30*6mm
Distance 1-5m
Time 300S

4. Warm note:

1)Pls use small ripple of power supply.The power supply voltage must meet the requirements.Also if the power supply current is too small,it can cause false positives or no detecting.

2)When you test the module,pls check if there is anybody within distance 1M.

3)Test In indoor is very sensitive.You shall test when there is no signal output .

4)Please note module output current is very weak, too much drive current is also easy to cause false positives.

5)Can not detect through Metal case

Best Regards
Ms.Cindy
ShenZhen Haiwang Sensor Co.,Ltd
Phone:86-18682200597
Tel:86-755-82867860 ext 615 
Fax:86-755-82867870
 
 
 
 
http://www.szhaiwang.cn/en/
  Microwave Motion Sensor Module Doppler Radar Detector(HW-M08)

1.Detail:
HW - M08 microwave module adopts the planar antenna transmitting and receiving. Induction object for moving objects (or car), after induction to the output voltage signal, for active microwave induction, induction angle is 90degree.Widely used in security monitoring, intelligent systems, control of lamps and lanterns, automatic doors, garage, corridor, roads etc

2.Features:
1).Not affected by temperature, humidity, air, dust, noise, light and dark, not affected by the direction of movement, strong anti-jamming capability.
2) Microwave module is a pattern to launch out, no dead Angle blind area, wide coverage.
3)Microwave is reflected more easily in the process of transmission, sensitivity inside will be better, outdoor is a bit poor.
4)Signal can pass through the glass, obstacles such as trees, plastic (this will make the induction distance attenuation somewhat)
5) Professional design planar with antenna, low power consumption, ROHS, high product consistency.

We can custom the module as your request,welcome to ask me.OEM is highly welcomed.

3.Technical parameters:
Frequency 10.525GHZ
Current <5mA
Input Voltage 6-24V
Output Voltage 5V
Size 13.5*30*6mm
Distance 1-5m
Time 300S

4. Warm note:

1)Pls use small ripple of power supply.The power supply voltage must meet the requirements.Also if the power supply current is too small,it can cause false positives or no detecting.

2)When you test the module,pls check if there is anybody within distance 1M.

3)Test In indoor is very sensitive.You shall test when there is no signal output .

4)Please note module output current is very weak, too much drive current is also easy to cause false positives.

5)Can not detect through Metal case

Best Regards
Ms.Cindy
ShenZhen Haiwang Sensor Co.,Ltd
Phone:86-18682200597
Tel:86-755-82867860 ext 615 
Fax:86-755-82867870
 
 
 
 
http://www.szhaiwang.cn/en/
 

Oem Busbar

Oem Busbar,Flexible Busbar Manufacturers,Flexible Busbar Current Rating,Flexible Busbar Connections

Flexible Busbar,Bended Rigid Busbar Co., Ltd. , http://www.nbrigidbusbar.com